Ranfac RAN-1115N — 11 Gauge × 15 cm Bone Marrow Aspiration Needle (Non-Fenestrated), single-use, sterile
FDA Cleared · K131157 Single Use · Sterile EO Latex-Free
Bone Marrow Aspiration · Non-Fenestrated

11 Gauge × 15 cm Bone Marrow Aspiration Needle (Non-Fenestrated)

Single-use 11 gauge × 15 cm bone marrow aspiration needle with a non-fenestrated (closed-tip) cannula. The non-fenestrated companion to the standard RAN-1115 for protocols requiring single-site distal-tip aspiration at deeper-access length.

CatalogRAN-1115N
Part #74066-15M
Gauge11 G
Length15 cm
CannulaNon-Fenestrated
StyletSharp Diamond Tip

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.

Overview

The Ranfac RAN-1115N is an 11 gauge × 15 centimeter single-use bone marrow aspiration needle with a non-fenestrated (closed-tip) cannula. It is the non-fenestrated companion to the standard RAN-1115 (74062-15M) — same gauge, same deeper-access 15 cm working length, but with single-site distal-tip aspiration rather than side-port multi-site draw. Each needle ships sterile, ethylene-oxide processed, and individually packaged.

RAN-1115N is the non-fenestrated 15 cm companion to the standard RAN-1115 fenestrated needle. Selected when protocol calls for single-site distal-tip aspiration at deeper-access length, rather than the side-port multi-site draw the fenestrated RAN-1115 provides.

Clinical Applications

The Ranfac Bone Marrow Aspiration Needle is intended for use in aspirating bone marrow, as determined by a licensed physician.

This is a specialty configuration in the Ranfac K131157 BMA family — typically supplied for OEM, private-label, or custom-protocol applications. Indications and intended use follow the family clearance.

OEM / Private-Label

Reference design supplied as part of a custom or private-label BMA program.

Specialty Configuration

Variant of the standard Ranfac BMA platform with non-standard cannula, stylet, or kit-content modification.

Same Regulatory Path

Cleared under the Ranfac BMA family 510(k) K131157 — same Class II, KNW product code, 21 CFR 876.1075 regulation as the standard portfolio.

Outpatient & Inpatient Settings

Used across hospital hematology and oncology suites, ambulatory surgery centers, and procedure rooms performing routine marrow harvests.

Specifications

RAN-1115N Technical Data

Construction, regulatory, and packaging details. Gauge, length, cannula and stylet are listed in the hero above. For complete indications, contraindications, and warnings, download the Instructions for Use.

ConstructionStainless steel cannula and stylet · medical-grade polymer hub
ConnectionFemale luer-lock (accepts standard male luer-lock syringe)
SterilizationEthylene oxide · single-use · latex-free
PackagingIndividually pouched
FDA Clearance510(k) K131157 (22 Oct 2013) · Class II · 21 CFR 876.1075 · Product Code KNW
PrescriptionRx only (21 CFR 801 Subpart D)

Directions for Use (Summary)

The following is a summary only. The complete 10-step Instructions for Use, contraindications, warnings, and disposal requirements are provided in the IFU below.

  1. Inspect packaging. Confirm integrity; if undamaged, open using aseptic technique.
  2. Inspect the device. Check the cannula and stylet cutting edges for damage or imperfections.
  3. Adjust stiffener (if present) to the desired effective length.
  4. Position the needle adjacent to the aspiration site per proper placing technique.
  5. Advance the needle with gentle, firm pressure in alternating clockwise–counterclockwise rotation. Entry into the marrow cavity is generally signaled by decreased resistance.
  6. Remove the stylet by rotating the stylet cap counterclockwise.
  7. Attach a male luer-lock syringe to the needle hub. Avoid glass syringes — they may not seal properly and can fracture.
  8. Apply negative pressure by quickly withdrawing the plunger; disengage and recover the sample.
  9. Dispose of the used device in a sharps biohazard container, per applicable laws and your facility's biohazard policy.

Documents & Downloads

Frequently Asked Questions

What is the RAN-1115N?

A specialty configuration in the Ranfac K131157 BMA family. Variants of this kind are typically built for OEM or private-label programs; exact gauge, length, cannula and stylet geometry are confirmed per order.

Is the RAN-1115N FDA cleared?

Yes. It is cleared as part of the Ranfac Bone Marrow Aspiration Needle family under 510(k) K131157, regulation 21 CFR 876.1075, product code KNW, device Class II, prescription-use only.

How is the needle sterilized? Is it latex-free?

Sterilized by ethylene oxide (EO) and shipped sterile. The device is not made with natural rubber latex and is intended for single-patient use only.

How can I get specs and pricing on this configuration?

Specialty variants are typically supplied through a Ranfac OEM or private-label program. Contact us for spec sheets, sample pricing, or to start a custom program.

What does it relate to in the standard portfolio?

It's part of the Ranfac BMA family — most clinicians work from the standard configurations like the RAN-1115 (11 G × 15 cm fenestrated) or RAN-815 (8 G × 15 cm fenestrated). Specialty variants modify one or more of those baseline characteristics.

Can the configuration be modified further for a custom program?

Yes. Every Ranfac BMA configuration is built on the same vertically integrated platform we use for custom CDMO and CMO programs. Contact us to discuss requirements.

Related Products

Other configurations in the Ranfac Bone Marrow Aspiration family.

RAN-1115 — 11 Gauge × 15 cm Bone Marrow Aspiration Needle (Fenestrated)

RAN-1115

Single-use bone marrow aspiration needle with side-port (fenestrated) cannula

View →
RAN-11N — 11 Gauge × 11 cm Bone Marrow Aspiration Needle (Not Fenestrated)

RAN-11N

Single-use 11 gauge × 11 cm bone marrow aspiration needle with non-fenestrated cannula and diamond-tip stylet

View →
RAN-815N — 8 Gauge × 15 cm Bone Marrow Aspiration Needle (Not Fenestrated)

RAN-815N

Single-use 8 gauge × 15 cm bone marrow aspiration needle with non-fenestrated cannula and diamond-tip stylet

View →
RAN-823CM — 8 Gauge × 25 cm Bone Marrow Aspiration Needle (Non-Fenestrated, Trocar Stylet)

RAN-823CM

Single-use 8 gauge × 25 cm long-length bone marrow aspiration needle with non-fenestrated cannula and trocar-tip stylet

View →

Order or Request a Sample of the RAN-1115N

Have a clinical question, need samples for evaluation, or ready to purchase? Our product team typically responds within one business day.

Request a Quote → Request Samples

Building a different device on the same platform? Ranfac runs custom OEM, CDMO, and CMO programs from concept through commercial. Talk to us about a custom configuration →