ISO 13485 · MDSAP · EU MDR · FDA Registered
1-800-272-6322info@ranfac.com
Ranfac RAN-154 — 15 gauge × 4 inch bone marrow aspiration needle, single-use, sterile
FDA Cleared · K131157 Single Use · Sterile EO Latex-Free
Bone Marrow Aspiration · Small-Bore

15 Gauge × 4″ Bone Marrow Aspiration Needle

Single-use 15 gauge × 4 inch bone marrow aspiration needle. The smaller-bore configuration in the Ranfac BMA portfolio at standard 4 inch reach — for lower-volume diagnostic aspiration or specialized protocols.

CatalogRAN-154
Part #74047-04M
Gauge15 G
Length4″ (10.2 cm)
SterilitySterile (EO)
UseSingle Use

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.

Overview

The Ranfac RAN-154 is a 15 gauge × 4 inch single-use bone marrow aspiration needle. The 4 inch (10.2 cm) working length matches the standard reach used across hematology aspiration, with the smaller 15 gauge bore selected for protocols where lower volume or smaller-bore access is preferred. Each needle ships sterile, ethylene-oxide processed, and individually packaged.

RAN-154 is the standard-length 15 G configuration in the Ranfac BMA portfolio at a 4 inch (10.2 cm) working length. The shorter RAN-1582 (RAN-15(2.8)) covers the same gauge at 2.8 inches. Both are selected when a smaller-bore device is preferred over the standard 11 G workhorse configurations.

Clinical Applications

The Ranfac Bone Marrow Aspiration Needle is intended for use in aspirating bone marrow, as determined by a licensed physician.

Practitioners select 15 gauge × 4 inch aspiration needles for lower-volume diagnostic harvests, thin-cortex or smaller-anatomy applications, and OEM-specified configurations where the standard 11 G or 8 G bore is not appropriate.

Hematology & Oncology

Diagnostic marrow evaluation, lymphoma and leukemia workups, treatment monitoring, and metastatic staging.

Orthopedic & Spine

Marrow harvest for orthobiologic preparations used adjunctively to surgical procedures, per physician direction.

Interventional Radiology

Image-guided aspiration where smaller-bore access or controlled marrow draw is preferred.

Outpatient & Inpatient Settings

Used across hospital hematology and oncology suites, ambulatory surgery centers, and procedure rooms performing routine marrow harvests.

Specifications

RAN-154 Technical Data

Construction, regulatory, and packaging details. Gauge, length, cannula and stylet are listed in the hero above. For complete indications, contraindications, and warnings, download the Instructions for Use.

ConstructionStainless steel cannula and stylet · medical-grade polymer hub
ConnectionFemale luer-lock (accepts standard male luer-lock syringe)
SterilizationEthylene oxide · single-use · latex-free
PackagingIndividually pouched
FDA Clearance510(k) K131157 (22 Oct 2013) · Class II · 21 CFR 876.1075 · Product Code KNW
PrescriptionRx only (21 CFR 801 Subpart D)

Directions for Use (Summary)

The following is a summary only. The complete 10-step Instructions for Use, contraindications, warnings, and disposal requirements are provided in the IFU below.

  1. Inspect packaging. Confirm integrity; if undamaged, open using aseptic technique.
  2. Inspect the device. Check the cannula and stylet cutting edges for damage or imperfections.
  3. Adjust stiffener (if present) to the desired effective length.
  4. Position the needle adjacent to the aspiration site per proper placing technique.
  5. Advance the needle with gentle, firm pressure in alternating clockwise–counterclockwise rotation. Entry into the marrow cavity is generally signaled by decreased resistance.
  6. Remove the stylet by rotating the stylet cap counterclockwise.
  7. Attach a male luer-lock syringe to the needle hub. Avoid glass syringes — they may not seal properly and can fracture.
  8. Apply negative pressure by quickly withdrawing the plunger; disengage and recover the sample.
  9. Dispose of the used device in a sharps biohazard container, per applicable laws and your facility's biohazard policy.

Documents & Downloads

Frequently Asked Questions

What gauge and length is the RAN-154 bone marrow aspiration needle?

15 gauge with a 4 inch (10.2 cm) working length.

Is there a shorter 15 gauge version?

Yes — the RAN-1582 (15 G × 2.8 inch) is the shorter 15 gauge configuration.

When would I use 15 gauge instead of 11 gauge?

15 G is the smaller-bore, smaller-volume option — used for specialized protocols where the standard 11 G RAN-1115 is not appropriate.

Is the RAN-154 FDA cleared?

Yes. The Ranfac Bone Marrow Aspiration Needle family is cleared under 510(k) K131157, regulation 21 CFR 876.1075, product code KNW, device Class II, prescription-use only.

How is the needle sterilized? Is it latex-free?

Sterilized by ethylene oxide (EO) and shipped sterile. The device is not made with natural rubber latex and is intended for single-patient use only.

What syringe size works with this needle?

The female luer-lock hub accepts any standard male luer-lock aspiration syringe. Most operators select 10–20 mL syringes for routine marrow aspiration. Avoid glass syringes — they may not seal properly and can fracture during aspiration.

Related Products

Other configurations in the Ranfac Bone Marrow Aspiration family.

RAN-15(2.8) — 15 Gauge × 2.8″ Bone Marrow Aspiration Needle

RAN-15(2.8)

Single-use 15 gauge × 2

View →
RAN-1115 — 11 Gauge × 15 cm Bone Marrow Aspiration Needle (Fenestrated)

RAN-1115

Single-use bone marrow aspiration needle with side-port (fenestrated) cannula

View →
RAN-11 — 11 Gauge × 11 cm Bone Marrow Aspiration Needle (Fenestrated)

RAN-11

Single-use 11 gauge × 11 cm bone marrow aspiration needle with side-port (fenestrated) cannula and diamond-tip stylet

View →
RAN-815 — 8 Gauge × 15 cm Bone Marrow Aspiration Needle (Fenestrated)

RAN-815

Single-use 8 gauge × 15 cm bone marrow aspiration needle with side-port (fenestrated) cannula and diamond-tip stylet

View →

Order or Request a Sample of the RAN-154

Have a clinical question, need samples for evaluation, or ready to purchase? Our product team typically responds within one business day.

Request a Quote → Request Samples

Building a different device on the same platform? Ranfac runs custom OEM, CDMO, and CMO programs from concept through commercial. Talk to us about a custom configuration →